Model
Series CP
- Single Zone
Air
Handlers |
|
|
Single
zone central plant air handlers,
1,000 - 50,000 CFM, draw-through,
horizontal and vertical, single
and double wall, low, medium
and high pressure. |
l
|
Model
CLP |
|
Low
pressure (0.01 - 3.00 in w.g.
TSP). |
l |
Model
CMP |
|
Medium
pressure (3.01 - 6.00 in w.g.
TSP). |
l |
Model
CHP |
|
high
pressure (6.01 - 8.00 in w.g.
TSP) |
|
Model
Series MT
- Multizone Air Handlers |
|
Multizone
blow-through air handlers; 1,000
- 45,000 CFM; horizontal and
vertical; single and double wall;
low, medium and high pressure |
l
|
Model
MLT |
|
Low
pressure (0.01 - 3.00 in w.g.
TSP). |
l |
Model
MMT |
|
Medium
pressure (3.01 - 6.00 in w.g.
TSP). |
l |
Model
MHT |
|
High
pressure (6.01 - 8.00 in w.g.
TSP) |
Model
HT
- Heating and
Ventilating
Units
|
|
Heating
and ventilating units; 1,000
- 32,000 CFM; horizontal and
vertical; single and double wall;
low pressure heating unit variation
of basic model CLP. Medium
and high pressure and larger
units available as custom equipment. |
Model
FS
- Fan Sections |
|
Fan
Sections; 1,000 - 32,000 CFM;
horizontal and vertical; single
and double wall; low pressure
variation of basic model CLP. Medium
and high pressure and larger
units available as custom equipment. |
More >> |
|
 |
 |
 |
 |
 |
 |
|
|
 |
 |
 |
 |
 |
 |
ROOF
TOP AIR CONDITIONING
UNITS |
| |
l
|
Models
RTA and RTAU |
|
|
Single
zone rooftop air handlers,
1,000 - 32,000 CFM, without
(RTA)
or with (RTAU)
internal piping vestibules,
single and double wall, low
medium and high pressure. |
l
|
Models
RTM and RTMU |
|
|
Multizone
rooftop air handlers, 1,000
- 32,000 without (RTM)
or with (RTMU)
internal piping vestibule,
single and double wall, low,
medium and high pressure. |
l |
Model
RTHU |
|
|
Single
zone hospital rooftop air handlers
with internal piping vestibule,
blow-through final filter and
solid galvanized steel liner
downstream of final filter |
Units
may be curb- or pad-mounted. Larger
units are available as custom
equipment. Units are constructed
with galvanized steel panels attached
to galvanized, die-formed, welded
steel frames. Roofs are pitched
and fitted with standing ridge
cap and integral drip ledge.
All rooftop units feature
a solid galvanized steel
roof liner and lined hinged
access doors. Fully lined double
wall construction is available.
See specifications below for a
listing of standard and optional
features. |
| |
|
 |
 |
 |
 |
 |
 |
|
|
 |
 |
 |
 |
 |
 |
|
| |
|
Model
Series
THD, THB -Cabinet
Types P, C and D |
|
|
Five
sizes of Thermaire fan coil
units are designed for nominal
air flow rates of 600 - 3,000
CFM at pressures to 1.0" TSP.
Fan coil units are available
in six Model and Type configurations |
l
|
Two
Dive Configurations: |
|
|
Belt-drive
Model THB. |
| |
|
Direct-drive
Model THD. |
l
|
Three
Cabinet Types:
P, C and D |
|
|
Type
P, primary unit without cabinet |
| |
|
Type
C, primary unit with return air
plenum, designed for concealed
installation |
| |
|
Type
D, unit completely enclosed in
an attractive, painted deluxe
cabinet designed for exposed
installation |
l
|
Models
THB-P
and THD-P |
|
|
Type
P, Belt and Direct Drive Primary
Units |
l |
Models
THB-C
and THD-C |
|
|
Type
C, Belt and Direct Drive Concealed
Units |
l
|
Models
THB-D
and THD-D |
|
|
Type
D, unit completely enclosed in
an attractive, painted deluxe
cabinet designed for exposed
installation |
More >> |
|
 |
 |
 |
 |
 |
 |
|
|
 |
 |
 |
 |
 |
 |
HEAT
WHEEL UNITS
/ HEAT
RECOVERY
AIR HANDLERS |
| |
l
|
Standard
Units |
|
|
3,000
to 30,000 CFM |
| l |
Custom
Units |
|
3,000
to 60,000 CFM |
| l |
Standard
Feature |
|
Base:Structural
steel.
Frame:Welded
galvanized steel.
Casing:Mill-galvanized
steel.
Insulation:2",
1-½ pcf, NFPA coated glass
fiber.
Fans:SISW
air foil plenum.
Motors:208-230-460/3/60
ODP.
Fan
Base:Structural steel frame with
1"deflection spring isolators.
Filters:30%
pleated. |
l
|
Popular
Options |
|
|
Factory paint.
Double-wall construction.
Optional Insulation type and
thickness.
Dampers and louvers.
Water, steam and refrigerant
coils.
Electric
heaters.
Vapor tight lights and convenience
outlets.
Motor
starters, disconnects and
VFD’s.
ETL listed units.
Custom dimensions and features. |
|
|
|
|
|
Outdoor,
curb- or pad-mounted air handlers
featuring rotary heat exchangers
for energy recovery applications.
Larger units are available
as custom equipment. Units
are constructed with galvanized
steel panels attached to galvanized,
die-formed, welded steel frames.
Roofs are pitched and fitted
with standing ridge cap and
integral drip ledge. All units
feature a solid galvanized
steel roof liner and lined
hinged access doors. Fully
lined double wall construction
is available. |
More >> |
|
 |
 |
 |
 |
 |
 |
|
|
 |
 |
 |
 |
 |
 |
DOUBLE
WALL
/ SURPLUS
AHU'S |
| |
l
|
Available
for |
|
|
Models:
CPE, CP, MT, RT, RX and Custom
Air Handlers. |
| l |
Standard
Features |
|
-
Formed and welded, galvanized steel
frame, fully insulated and lined.
- Galvanized steel exterior panels.
- 20 ga (22 ga for CPE) galvanized
steel liner panels.
- Gasketed and screwed exterior
panels and hinged access doors.
- 2", 1-1/2" insulation for RT
models, 1" think for CPE, CP and
MT models.
- Double drain pan.
|
| l |
Options |
|
A
full range of options and accessories
are available. Popular options
include:
- Stainless steel drain pan liners.
- Special insulation materials and thickness.
- Perforated liner panels.
- Stainless steel and aluminum casings and liners.
- Explosion proof construction.
- Special sectional and bolted construction for limited installation
access.
- Factory-applied coatings.
- Air foil and plenum fans.
- Stainless steel and aluminum fan wheels and housings.
- Lights and convenience receptacles.
- Disconnects and motor controls
- Weatherproof casings.
- Performance testing.
- Third party filters, dampers, humidifiers, sound attenuators, controls,
and other components.
- Consult the Engineering Manuals for additional information. |
| l |
Dimensions |
|
For
CPE, CP and MT units, interior
width and height dimensions (air
flow cross-section) are identical
to our standard single wall unit
dimensions as illustrated in
the CP Engineering Manuals. Insulation
thickness greater than 1" increases
the overall height and width.
For RT units with insulation
thickness of 2" or less, dimensions
are as shown in our RT Engineering
Manual. Insulation thickness
greater than 2" increases the
overall height and width. Unit
length varies with the type and
number of desired components
- consult the Engineering Manuals
for approximate dimensions or
contact the factory. |
l
|
Coils |
|
|
THERMAL manufactures
a wide choice of efficient
coils for water, steam and
DX service. A complete selection
of premium materials, coatings
and accessories is also available.
-
Tubes: 5/8" copper tubes are standard.
Steel, stainless steel and exotic
materials are also available.
-
Fins: Plate fin materials are aluminum
and copper. (Stainless steel plate
fins are also available).
- Casings:
Standard is galvanized steel, optional 304 and 316L stainless steel
casings are available.
- Coatings:
Optional epoxy and phenol ic coil coatings are available. |
|
|
|
|
|
The
following are new, surplus THERMAL air
handlers which are available
for immediate shipment. Each
can be equipped with alternate
coils, drives, motors, accessories
and options. Contact the factory
for more information.
950
CFM: S/N 1-8440-01,
Show Unit. Horizontal drawthrough
unit. CLP-31-H, Fig 1011, 1" single
wall, aluminum casing,
950 cfm @ 1.0" TSP, FC fan, ½ HP
ODP, 110V external motor, 6-row
Cu/Al DX coil, 304 SS drain pan,
flat filter section. |
More >> |
|
 |
 |
 |
 |
 |
 |
|
|
 |
 |
 |
 |
 |
 |
|
| |
|
Available
for |
|
|
Thermal
offers efficient platefin coils
for all types of heating, cooling
and refrigerant condensing service. |
| |
Platefin
Coils |
|
-
Standard 5/8" tube arrangement
provides for universal application.
- Whether
provided as air handler components or as individual replacement coils,
Thermal's platefin coils are consistently available with the industry's
quickest delivery.
- Cost-effective
choice for most applications. |
|
Platefin
Coils
Spec. |
|
Service |
Water,
DX & Steam |
| Tube |
Material |
Standard: |
Seamless
Copper |
| Optional: |
Cu-Ni,
Stainless Steel, Carbon Steel |
| Thickness |
Standard: |
0.020" |
| Optional: |
0.025",
0.030" & 0.035" |
| Fin |
Material |
Standard: |
Aluminum |
| Optional: |
Copper |
| Thickness |
Standard: |
0.006" |
| Optional: |
0.008",
0.010" |
| Spacing |
Standard: |
10
fins/inch |
| Optional: |
8
- 14 fins/inch (.010" fin limited
to 11 fpi) |
| Casing |
Material |
Standard: |
Gal.
steel, tubesheets have smoothly
formed, rounded collars |
| Optional: |
304 & 316
Stainless Steel |
| Thickness |
Standard: |
16
Gauge |
| Test
Pressure |
400
psig |
|
Heating
and cooling coils: Types DX, W,
SS and SD: Platefin coils
- 1/2" DX, water and steam
- 5/8" DX, water and steam
- 1" Steam Distributing |
More >> |
|
 |
 |
 |
 |
 |
 |
|
|
 |
|
|